Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04264724 Cty MRN Rte 101 PM R20.8/27.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Fabio La Serna |
Date Reported: |
01/19/2023 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
||||
Prime Contractor: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO) |
||||
Sample Taken Date: |
12/22/2022 |
Mix Design: |
3728LV-SRA-Fibers |
|
Contractor: Unknown |
Location : MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
|||
Structure unique identifier: 27-0092L |
||||
Structure name: Olive Ave UC - Widen SB |
||||
Location of Pour: Deck Olive Ave UC widen |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 58173 | 4583.0 | 1 |
2 | 4.01 | 12.63 | 60785 | 4813.0 | 1 |
3 | 4.01 | 12.63 | 63561 | 5033 | 1 |
DIME Test ID: 2022-12-22-1-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4810
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 82193 | 6508.0 | 1 |
2 | 4.01 | 12.63 | 86210 | 6826.0 | 1 |
3 | 4.00 | 12.57 | 83431 | 6639 | 1 |
DIME Test ID: 2022-12-22-1-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6660
Age of specimen: 12 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 88406 | 6965.0 | 1 |
2 | 4.01 | 12.63 | 86834 | 6876.0 | 1 |
3 | 4.01 | 12.63 | 83550 | 6616 | 1 |
DIME Test ID: 2022-12-22-1-4
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6820
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 98096 | 7767.0 | 1 |
2 | 4.01 | 12.63 | 91957 | 7281.0 | 1 |
3 | 4.01 | 12.63 | 92461 | 7321 | 1 |
DIME Test ID: 2022-12-22-1-5
Number of specimens: 3
Compressive strength (to nearest 10 psi): 7460
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.03 | 12.76 | 47999 | 3763.0 | 1 |
2 | 4.01 | 12.63 | 51917 | 4111.0 | 1 |
3 | 4.01 | 12.63 | 47444 | 3757 | 1 |
DIME Test ID: 2022-12-22-1-6
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3880
Age of specimen: 8 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
![]() |
TL- Report of Laboratory Testing