Print Report | Back to Sample Detail

Sample Record for 2022-10-29-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993287 DEA: 112T35U4 EFIS: 1121000195 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-R37.4/R52.6
Work Description: CMSTPL-6211(148) I-5 N Coast Corridor HOV Extension Carlsbad
Location Description: IN SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM LOMAS SANTA FE DRIVE UNDERCROSSING TO 0.2 MILES NORTH OF OCEANSIDE BOULEVARD UNDERCROSSING
Contractor Name: Flatironcorp
Contractor Address: 1525 Faraday Avenue, Suite 180, Carlsbad, CA 92008
Resident Engineer: Steve McMillan Structure Rep.: Rafael Lopez

Sample Information

DIME Sample ID: 2022-10-29-10
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/29/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/30/2022
The quantity of what the sample constitutes: 2 cylinders
A brief description of the sample: Structural Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cal portland

Material Information

The concrete mix design number: 0038621
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 105508
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SB Approach Departure SB AHL Approach Departure SB Chestnu
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-10-29-10-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/16/2022
Date Tested: 12/10/2022
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5160 psi
Maximum load on cylinder 1 141900 lb
Maximum load on cylinder 2 149750 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 42 days
Age of specimen in hours 0 hours