Sample Record for 2022-12-15-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213750 DEA: 120K0224 EFIS: 1214000097 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-14.5/17.1
Work Description: South County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
Contractor Name: Flatiron West, Inc
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, California 92078
Resident Engineer: Steven Kim Structure Rep.: Sara Soleimani

Sample Information

DIME Sample ID: 2022-12-15-1
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Authorization
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 12/15/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/19/2022
The quantity of what the sample constitutes: N/A
A brief description of the sample: A775 Epoxy Coated Dowel
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: American Highway - Simplex

Material Information

Dowel Metal Heat Number: 3500028871
Dowel Epoxy Batch Number: CH2842CR
Dowel Coating Specification: ASTM A775
Dowel Size: 1.5 in
Dowel Coating Color: Green
Dowel Manufacturer: Newcor
Dowel Coater: American Highway Simplex
Release Number:
Quality Assurance Code:
Rebar Size (#):

Test Results

Test 1 of 2

DIME Test ID: 2022-12-15-1-1
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 01/05/2023
Date Tested: 12/29/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 10.06
Second Bar Mean 12.2
Lower spec. limit LSL 7 mils
Upper spec. limit USL 40 mils
Total mean value 11.13
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2022-12-15-1-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 01/05/2023
Date Tested: 12/29/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 3
Holidays Per Linear Foot of Bar 0
Holiday Test Pass/Fail Pass