Project ID: 215663 DEA: 060Y9304 EFIS: 0619000202
QA Service Level: 1
DIST-CO-RTE-PM: 06-KIN-198-R10.6/R14.8
Work Description: REPAIR BRIDGE COLUMNS.
Location Description: KINGS COUNTY IN AND NEAR LEMOORE AND ARMONA FROM 18TH AVENUE OVERCROSSING TO 14TH AVENUE UNDERCROSSING
Contractor Name: BOSCO CONSTRUCTORS INC
Contractor Address: 21353 MAYALL ST., CHATSWORTH CA 91311
Resident Engineer: Felix Vaquilar Structure Rep.: Nathan Quiroz
DIME Sample ID: 2022-11-21-40
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/22/2022
The quantity of what the sample constitutes: Unknown
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown
The concrete mix design number: ND21548
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-11-21-40-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/13/2022
Date Tested: 12/09/2022
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
3.99 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.5 in^2
|
Compressive strength (to nearest 10 psi)
|
5110 psi
|
Maximum load on cylinder 1
|
61280 lb
|
Maximum load on cylinder 2
|
65890 lb
|
Maximum load on cylinder 3
|
65150 lb
|
Compressive strength of cylinder 1
|
4875.1 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
5241.8 psi
|
Compressive strength of cylinder 3
|
5212 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
17 days
|
Age of specimen in hours
|
0 hours
|