Print Report | Back to Sample Detail

Sample Record for 2022-11-21-32

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214438 DEA: 080G6914 EFIS: 0815000184 QA Service Level: 1
DIST-CO-RTE-PM: 08---
Work Description: RELINE OR REPLACE CULVERTS
Location Description: SAN BERNARDINO COUNTY IN AND NEAR SAN BERNARDINO FROM 48TH STREET TO ROUTE 18/138 SEPARATION
Contractor Name: SUKUT CONSTRUCTION, LLC.
Contractor Address: Unknown
Resident Engineer: NHAN NGUYEN Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-21-32
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Asphalt Binder
Sample Taken Date: 11/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/01/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: PG Asphalt Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0762-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Matich Lytle Creek

Material Information

Performance Grade: PG 64-28
Modified: Yes
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Marathon Petroleum Co. LP - Tuscon AZ
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2022-11-21-32-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: -0.104 + 0.006 = 0.098
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Any material loss from containers during heating process/testing? No
Mass of empty container #1 167.289 grams
Mass of empty container #2 169.569 grams
Mass of container #1 before test (m1i) 202.352 grams
Mass of container #2 before test (m2i) 204.703 grams
Mass of container #1 after test (m1f) 202.315 grams
Mass of container #2 after test (m2f) 204.667 grams
Average mass change -0.104 percent

Test 2 of 7

DIME Test ID: 2022-11-21-32-2
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: ORIGINAL
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Phase Angle (δ) (for the 10 cycles) 55.7 degree
Dynamic Shear, G*/sin(δ) 1.93 kPa
(G*) x sin(δ)= no data

Test 3 of 7

DIME Test ID: 2022-11-21-32-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Plate Diameter 25 mm
Phase Angle (δ) (for the 10 cycles) 63.3 degree
Dynamic Shear, G*/sin(δ) 2.58 kPa

Test 4 of 7

DIME Test ID: 2022-11-21-32-4
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test 8:45 HH:MM
Test Temperature 135 C
Speed 20 rpm
Spindle size 21 in
Torque 79 %
Viscosity reading #1 (A) 1.978 Pa-s
Viscosity reading #2 (B) 2.004 Pa-s
Viscosity reading #3 (C) 1.981 Pa-s
Average viscosity 1.988 Pa-s

Test 5 of 7

DIME Test ID: 2022-11-21-32-5
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Specific Gravity 1.045

Test 6 of 7

DIME Test ID: 2022-11-21-32-6
Test Method: AASHTO T44-18: Standard Method of Test for Solubility of Bituminous Materials
Verified Date: 12/09/2022
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Was test performed on residue from distillation or evaporation? NA
Soluble, percent 99.3 %
Insoluble, percent 0.7 %

Test 7 of 7

DIME Test ID: 2022-11-21-32-7
Test Method: AASHTO T301-22: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
Data has not been verified.