Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993607 DEA: 07322604 EFIS: 0716000057
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R41.3/R44.6
Work Description: CONSTRUCT POLLUTION INFILTRATION AREAS AND AUSTIN VAULT SAND FILTER.
Location Description: LOS ANGELES COUNTY IN GLENDORA AT VARIOUS LOCATIONS FROM 0.2 MILE EAST OF BARRANCA AVENUE OVERCROSSING TO 0.1 MILE WEST OF AMELIA AVENUE UNDERCROSSING
Contractor Name: SEMA CONSTRUCTION
Contractor Address: 42690 Rio Nedo, Temecula, CA 92590
Resident Engineer: Raj Punjabi Structure Rep.: Unknown
DIME Sample ID: 2022-12-01-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 12/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/01/2022
The quantity of what the sample constitutes: 560 SF
A brief description of the sample: Subgrade
From where was the sample collected: Job Site
Laboratory sample identification: 22-3126
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA
The fabricator's/manufacturer's product name for the sample: Subgrade
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Various locations
Where the material sample would have been placed if not sampled:
DIME Test ID: 2022-12-01-8-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 12/02/2022
Date Tested: 12/01/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test: MVP Located @
EB Rte. 210 Sunflower Off-Ramp
Sta. 92+09 to Sta. 92+89
Test Result Compliance:
Additional Comments When Verified:
Standard Count Density
|
2323 g/cc
|
Count or Density 1
|
2 g/cc
|
Count or Density 2
|
1.99 g/cc
|
Count or Density 3
|
1.93 g/cc
|
Standard Count Moisture
|
651 g/cc
|
Moisture Count 1
|
0.23 g/cc
|
Moisture Count 2
|
0.25 g/cc
|
Moisture Count 3
|
0.11 g/cc
|
Sum of Count or Density
|
5.92 g/cc
|
Average of Count or Density
|
1.97 g/cc
|
Sum of Moisture Count
|
0.59 g/cc
|
Average of Moisture Count
|
0.20 g/cc
|
Calculated Percent Relative Compaction
|
89.3 %
|
Reported Percent Relative Compaction
|
89 %
|
DIME Test ID: 2022-12-01-8-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 12/02/2022
Date Tested: 12/01/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test: MVP Located @
EB Rte. 210 Sunflower Off-Ramp
Sta. 92+09 to Sta. 92+89
Test Result Compliance:
Additional Comments When Verified:
Is oversize material
|
No
|
In-place wet density
|
1.97
|
Highest adjust wet density
|
2.21
|
Relative compaction
|
89
|
% Moisture
|
11.1 %
|
Optimum Moisture
|
no data
|