Print Report | Back to Sample Detail

Sample Record for 2022-12-01-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212880 DEA: 050F9704 EFIS: 0513000017 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-101-62.7
Work Description: N. SOLEDAD OH DECK REPLACEMENT
Location Description: ON RTE 101 IN MONTEREY COUNTY NEAR SOLEDAD AT THE NORTH SOLEDAD OH BRIDGE BR 44-0091L/R
Contractor Name: Graniterock Construction
Contractor Address: 5225 Hellyer Ave, Suite 220, San Jose, CA 95138
Resident Engineer: Baljinder Brar Structure Rep.: Dean Russu

Sample Information

DIME Sample ID: 2022-12-01-4
TL Number from the TL Form: 001
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 594-1991
Type of Sample: Quality Assurance
Type of Material: Rapid Set
Sample Taken Date: 12/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/10/2022
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: Rapid Set
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Master Emaco

Material Information

Manufacturer: Master Emaco
Mix no.: 3670
Materials Received: 10/24/2022
Lot no.: 3021235001
Batch no.: 3021235001

Test Results

Test 1 of 2

DIME Test ID: 2022-12-01-4-1
Test Method: CONCLP 2-16: Rapid Set Patching Materials
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 594-1991
This test has been superseded on 12/01/2022. The corrected test ID is: 2022-12-01-4-2
Reason: retested

Test 2 of 2

DIME Test ID: 2022-12-01-4-2
Test Method: CONCLP 2-16: Rapid Set Patching Materials
Verified Date: 01/24/2023
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
The test was superseded from test ID: 2022-12-01-4-1
Test Result Compliance: does not comply
Additional Comments When Verified:
Compressive Strength @ 3 hrs (CTM 551) 980
Compressive Strength @ 24 hrs (CTM 551) 3590
Flexure Strength @ 24 hrs (CTM 551) 0
Bond Strength @ 24 hrs - SSD (CTM 551) 0
Bond Strength @ 24 hrs - Dry (CTM 551) 0
Water Absorption (CTM 551) 0
Abrasion @ 24 hrs (CTM 550) 27
Drying Shrinkage @ 4 days (CTM 596) 0
Soluble Chlorides (CTM 422) 0
Water Soluble-Sulfates (CTM 417) 0
Material Weight 50
Water Weight 4.16