Print Report | Back to Sample Detail

Sample Record for 2022-11-23-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993805 DEA: 070W1404 EFIS: 0721000062 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-1-4.4/9.7
Work Description: COLD PLACE AC PAVEMENT AND PLACE RHMA-G.
Location Description: VENTURA COUNTY FROM BIG SYCAMORE MAINTENANCE STATION AND PARK TO 0.2 MILE SOUTH OF GALLEGUAS GREEK BRIDGE
Contractor Name: C A RASMUSSEN INC
Contractor Address: 28548 LIVINGSTON AVENUE, VALENCIA CA 91355
Resident Engineer: Ranjit Singh Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-23-14
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 11/23/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/29/2022
The quantity of what the sample constitutes: 4 Bags of Combined Aggregate
A brief description of the sample: 1/2" RHMA-G-SP 0.5% WMA
From where was the sample collected: Job Site
Laboratory sample identification: 0760G-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Saticoy

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0020
The fabricator's/manufacturer's product name for the sample: Vulcan Materials Saticoy
The fabricator/manufacturer designation for the sample: Vulcan Materials Saticoy
The plant number:
A detailed description of where the material sample was collected: Beltcut
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: 326122 SAT VLO
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 8

DIME Test ID: 2022-11-23-14-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/25/2023
Date Tested: 12/05/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test: Combined Virgin Aggregate Gradation
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 98 %
Cumulative percent passing the 3/8 in. sieve 82 %
Cumulative percent passing the #4 sieve 30 %
Cumulative percent passing the #8 sieve 17 %
Cumulative percent passing the #16 sieve 10 %
Cumulative percent passing the #30 sieve 7 %
Cumulative percent passing the #50 sieve 5 %
Cumulative percent passing the #100 sieve 3 %
Cumulative percent passing the #200 sieve 2.2 %

Test 2 of 8

DIME Test ID: 2022-11-23-14-2
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 01/25/2023
Date Tested: 11/03/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.602
Bulk specific gravity (SSD Basis) 2.644
Apparent specific gravity 2.716
Absorption 1.6 %

Test 3 of 8

DIME Test ID: 2022-11-23-14-3
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 01/25/2023
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.625
Absorption 1.2 %

Test 4 of 8

DIME Test ID: 2022-11-23-14-4
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 01/25/2023
Date Tested: 12/03/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation C
Mass of sample on No.12 sieve (after 500 revolutions) 3395 grams
Percent loss after 100 revolutions 7 %
Percent loss after 500 revolutions 32 %

Test 5 of 8

DIME Test ID: 2022-11-23-14-5
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 01/25/2023
Date Tested: 12/01/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 76

Test 6 of 8

DIME Test ID: 2022-11-23-14-6
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 01/25/2023
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.602
Average uncompacted voids 44.7 %

Test 7 of 8

DIME Test ID: 2022-11-23-14-7
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 01/25/2023
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Percentage of fractured, coarse, 2 faced particles tested 100 %
Percentage of fractured, coarse, 1 faced particles tested 100 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 8 of 8

DIME Test ID: 2022-11-23-14-8
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 01/25/2023
Date Tested: 12/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method B
Determination By Mass
Dimensional ratio used 5:1
Weighted percentage of particles (by mass) that were flat and elongated 0 %
Weighted percentage of particles (by mass) that were not flat and elongated 100 %