Project Information

Project ID: 993336 DEA: 07328804 EFIS: 0716000183 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-R54.4/R54.8
Work Description: BUILDING WORK.
Location Description: LOS ANGELES COUNTY IN SANTA CLARITA FROM NORTHBOUND OFF-RAMP TO NORTHBOUND ON-RAMP CASTAIC WEIGH STATION
Contractor Name: Kanaan Construction Inc.
Contractor Address: 230 S Irwindale Ave, Azusa, CA 91702
Resident Engineer: Mohammad Zakir Khan Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-14-47
TL Number from the TL Form: 221114
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 11/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2022
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 6X12 PCC cylinder
From where was the sample collected: Job Site
Laboratory sample identification: 22-0357
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertsons

Material Information

The concrete mix design number: SC590B38
The truck number from where the sample was collected: 1987
The batch plant ticket number from where the sample was collected: 1030581
Concrete batch plant: Robertsons
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2022-11-14-47-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/28/2022
Date Tested: 11/28/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 3680 psi
Maximum load on cylinder 1 104110 lb
Maximum load on cylinder 2 103408 lb
Compressive strength of cylinder 1 3694.5 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3669.6 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours 0 hours

Test 2 of 3

DIME Test ID: 2022-11-14-47-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/12/2022
Date Tested: 12/12/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 4000 psi
Maximum load on cylinder 1 110818 lb
Maximum load on cylinder 2 114886 lb
Compressive strength of cylinder 1 3932.5 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4076.9 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 0 hours

Test 3 of 3

DIME Test ID: 2022-11-14-47-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/03/2023
Date Tested: 12/26/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4820 psi
Maximum load on cylinder 1 135974 lb
Maximum load on cylinder 2 136781 lb
Compressive strength of cylinder 1 4809.8 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4838.4 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 42 days
Age of specimen in hours 0 hours