Print Report | Back to Sample Detail

Sample Record for 2022-11-18-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215374 DEA: 060X2704 EFIS: 0618000048 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-37.2/48.8
Work Description: PAVEMENT REHABILITATION
Location Description: FROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-11-18-38
TL Number from the TL Form:
Sample Submitted By Organization: Structure Cast
Sample Organization Contact: (661) 301-2624
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 11/18/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/21/2022
The quantity of what the sample constitutes: 9 CY
A brief description of the sample: Concrete Test Samples
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: StructureCast

Material Information

The concrete mix design number: 06-0X2704
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 7558
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from truck into wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-11-18-38-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/23/2022
Date Tested: 11/22/2022
Submitted By Organization: Structure Cast
Organization Address: 8261 McCutchen Road ,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93311
Organization Email: brent@structurecast.com
Organization Phone: (661) 301-2624
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 5920 psi
Maximum load on cylinder 1 164530 lb
Maximum load on cylinder 2 170185 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 4 days
Age of specimen in hours 0 hours