Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993195 DEA: 07332504 EFIS: 0716000270
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-2-26.4/79.8
Work Description: INSTALL METAL BEAM GUARDRAILS.
Location Description: LOS ANGELES COUNTY NEAR LA CANADA FLINTRIDGE FROM BAY TREE ROAD TO BIG PINES HIGHWAY
Contractor Name: DREAMBUILDER CONSTRUCTION CORP DBA DREAMBUILDER
Contractor Address: Unknown
Resident Engineer: Bill Tran Danglong Structure Rep.: Unknown
DIME Sample ID: 2022-11-16-13
TL Number from the TL Form: 019439
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/16/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/16/2022
The quantity of what the sample constitutes: 18 tons out
A brief description of the sample: 3/8" HMA DIKE
From where was the sample collected: Manufacturer
Laboratory sample identification: 22-0356
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Sun Valley
DIME Test ID: 2022-11-16-13-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/17/2022
Date Tested: 11/17/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
no data
|
Mass of the specimen and specimen basket assembly prior to ignition
|
no data
|
Mass of HMA Sample prior to ignition
|
1571.8 g
|
Corrected Asphalt Binder Content
|
6.46 %
|
Mass Loss
|
no data
|
Mass of aggregate remaining after ignition
|
1470.2 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000.4 F
|