Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214336 DEA: 07302404 EFIS: 0713000488
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-101-37/40
Work Description: PADRE JUAN REHAB
Location Description: VEN 101
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4820 McGrath Street, Suite 101, Ventura, CA 93003
Resident Engineer: Alfred Ira Structure Rep.: Unknown
DIME Sample ID: 2022-10-04-80
TL Number from the TL Form: 22-2649
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 10/04/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/05/2022
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 6x12 JPCP cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification: 22-2649
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Batch Plant
The concrete mix design number: G3-21-PCC-249R
The truck number from where the sample was collected: 6
The batch plant ticket number from where the sample was collected: 9005
Concrete batch plant: Granite Costruction Ventura
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Skip loader to wheel barrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-10-04-80-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/16/2022
Date Tested: 11/15/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.03 in
|
Average diameter of cylinder 2
|
6.02 in
|
Average diameter of cylinder 3
|
6.02 in
|
Cross sectional area of cylinder 1
|
28.56 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Cross sectional area of cylinder 3
|
28.46 in^2
|
Compressive strength (to nearest 10 psi)
|
6070 psi
|
Maximum load on cylinder 1
|
183531 lb
|
Maximum load on cylinder 2
|
164454 lb
|
Maximum load on cylinder 3
|
171261 lb
|
Compressive strength of cylinder 1
|
6426.2 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
5778.4 psi
|
Compressive strength of cylinder 3
|
6017.6 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
42 days
|
Age of specimen in hours
|
0 hours
|