Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994111 DEA: 061E2104 EFIS: 0621000226
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-8.0
Work Description: REPLACE JOINT SEALS, PREPARE AND PLACE POLYESTER CONCRETE OVERLAY.
Location Description: FRESNO COUNTY NEAR AVENAL AT ARROYO PASAJERO BRIDGE
Contractor Name: Peterson-Chase General Engineering Construction inc,
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Din Dadawalla Structure Rep.: Unknown
DIME Sample ID: 2022-06-15-78
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 06/15/2022
Date that the sample was received by the laboratory/organization performing the testing: 06/17/2022
The quantity of what the sample constitutes: 14 Totes
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: 943755
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2022-06-15-78-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 12/01/2022
Date Tested: 12/01/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2022-06-15-78-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 12/01/2022
Date Tested: 12/01/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
8.33
|
DIME Test ID: 2022-06-15-78-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 12/01/2022
Date Tested: 12/01/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted supplier result
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.486 in
|
Sample 1 Ultimate strength
|
24921.2 psi
|
Sample 1 Thickness
|
0.248 in
|
Sample 1 Area
|
0.1205 in^2
|
Sample 1 Ultimate Strength Actual
|
3003 lbs
|
Sample 1 percent elongation
|
62.1 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.487 in
|
Sample 2 Thickness
|
0.254 in
|
Sample 2 Area
|
0.1237 in^2
|
Sample 2 Ultimate strength
|
24987.9 psi
|
Sample 2 Ultimate Strength Actual
|
3091 lbs
|
Sample 2 percent elongation
|
64.8 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.487 in
|
Sample 3 Thickness
|
0.255 in
|
Sample 3 Area
|
0.1242 in^2
|
Sample 3 Ultimate strength
|
24750.4 psi
|
Sample 3 Ultimate Strength Actual
|
3074 lbs
|
Sample 3 percent elongation
|
64.7 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.486 in
|
Sample 4 Thickness
|
0.251 in
|
Sample 4 Area
|
0.122 in^2
|
Sample 4 Ultimate strength
|
25868.9 psi
|
Sample 4 Ultimate Strength Actual
|
3156 lbs
|
Sample 4 percent elongation
|
66.5 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.486 in
|
Sample 5 Thickness
|
0.257 in
|
Sample 5 Area
|
0.1249 in^2
|
Sample 5 Ultimate strength
|
24443.6 psi
|
Sample 5 Ultimate Strength Actual
|
3053 lbs
|
Sample 5 percent elongation
|
63.7 %
|
Sample 5 Time
|
0 MM:SS
|
Sample 6 Width
|
0.487 in
|
Sample 6 Thickness
|
0.261 in
|
Sample 6 Area
|
0.1271 in^2
|
Sample 6 Ultimate strength
|
24744.3 psi
|
Sample 6 Ultimate Strength Actual
|
3145 lbs
|
Sample 6 percent elongation
|
66.7 %
|
Sample 6 Time
|
0 MM:SS
|
Ultimate Strength Average
|
24953 psi
|
Percent Elongation Average
|
65 %
|
DIME Test ID: 2022-06-15-78-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 12/01/2022
Date Tested: 12/01/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mean of two volatile content determination
|
45.5
|
DIME Test ID: 2022-06-15-78-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 12/01/2022
Date Tested: 12/01/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1318.24 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
659.119 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1318.24 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
659.119 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1318.24 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
659.119 psi
|
DIME Test ID: 2022-06-15-78-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 12/01/2022
Date Tested: 12/01/2022
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted vendor results
Test Result Compliance:
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
77 f
|
Tare weight
|
0 grams
|
Initial weight
|
100.052 grams
|
Weight at 5 minutes
|
99.896 grams
|
Weight at 10 minutes
|
99.786 grams
|
Weight at 15 minutes
|
99.656 grams
|
Weight at 20 minutes
|
99.574 grams
|
Weight at 25 minutes
|
99.488 grams
|
Weight at 30 minutes
|
99.408 grams
|
Final weight
|
99.41 grams
|
Total weight loss
|
0.64 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
34.512 grams/m^2
|