Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993252 DEA: 030H6504 EFIS: 0316000003
QA Service Level: 1
DIST-CO-RTE-PM: 03-COL-20-34.8/36.5
Work Description: RDWY EXCAVATION, COLD PLANE AC PVMT, & OVERLAY.
Location Description: COLUSA COUNTY 1.7 MILES EAST OF COLUSA FROM NIAGARA AVENUE TO 0.3 MILE WEST OF STEIDLMAYER ROAD
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 400 Sunrise Ave, Suite 300, Roseville, CA 95661
Resident Engineer: Garrett Griffith Structure Rep.: Unknown
DIME Sample ID: 2022-10-08-16
TL Number from the TL Form: 802339
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 10/08/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/11/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: 1/2" RHMA-O PG 64-16 oil
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero - Benicia, CA
Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2022-10-08-16-1
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 11/17/2022
Date Tested: 11/16/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.186 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
84.9 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.554 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.56 kPa
|