Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 1900-01-01-1
TL Number from the TL Form:
Sample Submitted By Organization: Valero Benicia Refinery
Sample Organization Contact: (707) 745-7384
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 01/01/1900
Date that the sample was received by the laboratory/organization performing the testing: 01/01/1900
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Tank 30A
From where was the sample collected: Manufacturer
Laboratory sample identification: 1221000480
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Benicia, CA
Performance Grade: PG 64-28M
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Benicia Refinery
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 1900-01-01-1-1
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-2
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-3
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-4
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-5
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-6
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-7
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-8
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-9
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.
DIME Test ID: 1900-01-01-1-10
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Submitted By Organization: Valero Benicia Refinery
Organization Address: 3400 East 2nd Sreet,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: severino.gorospe@valero.com
Organization Phone: (707) 745-7384
Data has not been verified.