Project Information

Project ID: 993154 DEA: 120R3404 EFIS: 1218000079 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-73-12.9/R26.8
Work Description: REPLACE APPROACH SLABS, JOINT SEAL, AND APPLY METHACRYLATE ON BRIDGES.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM MOULTON PARKWAY UNDERCROSSING IN LAGUNA NIGUEL TO BRISTOL STREET UNDERCROSSING IN COSTA MESA
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 CONSTRUCTION CIR W, IRVINE, CA 92606
Resident Engineer: Nabil J. Ruda Structure Rep.: Ali Jenabzadeh

Sample Information

DIME Sample ID: 2022-10-08-15
TL Number from the TL Form: 265707
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/08/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/10/2022
The quantity of what the sample constitutes: 6 concrete cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 22-0390
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Shortload Mobile Mixers

Material Information

The concrete mix design number: CTS-72-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RTE 73 Approach Slabs Br
Where the material sample would have been placed if not sampled: LOC 10 S73 Bristol St Uc Br
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2022-10-08-15-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/03/2023
Date Tested: 10/15/2022
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test: @ 7 Days, Required = 2500 psi; Complies
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C39 - Ground End
Average diameter of cylinder 1 5.96 in
Average diameter of cylinder 2 5.96 in
Cross sectional area of cylinder 1 27.89 in^2
Cross sectional area of cylinder 2 27.89 in^2
Compressive strength (to nearest 10 psi) 5860 psi
Maximum load on cylinder 1 165300 lb
Maximum load on cylinder 2 161460 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours 0 hours

Test 2 of 2

DIME Test ID: 2022-10-08-15-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/03/2023
Date Tested: 11/05/2022
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test: @ 28 Days, required = 4000 psi; Complies
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C39 - Ground End
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.08 in^2
Cross sectional area of cylinder 2 28.36 in^2
Compressive strength (to nearest 10 psi) 6080 psi
Maximum load on cylinder 1 161740 lb
Maximum load on cylinder 2 181760 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 0 hours