Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993592 DEA: 120S8704 EFIS: 1221000056
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-55-0.2/T2.4
Work Description: COLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location Description: ORANGE COUNTY IN NEWPORT BEACH AND COSTA MESA FROM JUNCTION ROUTE 1 TO 0.4 MILE NORTH OF 19TH STREET
Contractor Name: CALMEX ENGINEERING INC.
Contractor Address: 2764 S VISTA AVE, BLOOMINGTON, CA 92316
Resident Engineer: Jay Joubeen Structure Rep.: Unknown
DIME Sample ID: 2022-09-12-63
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/12/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/01/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0719-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Irwindale
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2022-09-12-63-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/15/2022
Date Tested: 11/02/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
60 C
|
Softening Point Sample 2
|
60 C
|
Bath Liquid
|
freshly boiled distilled water
|
Minutes Reaction
|
no data
|
DIME Test ID: 2022-09-12-63-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 11/15/2022
Date Tested: 11/03/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination
|
Unworked Penetration
|
Unworked Penetration
|
35 0.1 mm
|
DIME Test ID: 2022-09-12-63-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 11/15/2022
Date Tested: 11/03/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
73 mm
|
Ball Penetration (P1)
|
2 mm
|
Final Dial reading (F2)
|
74 mm
|
Ball Penetration (P2)
|
3 mm
|
Final Dial reading (F3)
|
76 mm
|
Ball Penetration (P3)
|
3 mm
|
Resilience 1
|
29 %
|
Resilience 2
|
29 %
|
Resilience 3
|
27 %
|
Average Resilience
|
28 %
|
Minutes Reaction
|
no data
|