Print Report | Back to Sample Detail

Sample Record for 2022-10-25-62

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993805 DEA: 070W1404 EFIS: 0721000062 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-1-4.4/9.7
Work Description: COLD PLACE AC PAVEMENT AND PLACE RHMA-G.
Location Description: VENTURA COUNTY FROM BIG SYCAMORE MAINTENANCE STATION AND PARK TO 0.2 MILE SOUTH OF GALLEGUAS GREEK BRIDGE
Contractor Name: C A RASMUSSEN INC
Contractor Address: 28548 LIVINGSTON AVENUE, VALENCIA CA 91355
Resident Engineer: Ranjit Singh Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-10-25-62
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 10/25/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/28/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification: 0716-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Saticoy

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2022-10-25-62-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 11/16/2022
Date Tested: 11/01/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 25 0.1 mm

Test 2 of 3

DIME Test ID: 2022-10-25-62-2
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 11/16/2022
Date Tested: 11/01/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 60 mm
Ball Penetration (P1) 0 mm
Final Dial reading (F2) 60 mm
Ball Penetration (P2) 0 mm
Final Dial reading (F3) 59 mm
Ball Penetration (P3) 0 mm
Resilience 1 40 %
Resilience 2 40 %
Resilience 3 41 %
Average Resilience 40 %
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2022-10-25-62-3
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/16/2022
Date Tested: 10/31/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 71 C
Softening Point Sample 2 71 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data