Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215697 DEA: 07318204 EFIS: 0715000286
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-Route 1-4.0/4.2
Work Description: CM/GC Project - Work consists of constructing secant wall and slope restoration
Location Description: near Point Mugu State Park 0.4 mile South of Sycamore Canyon Road.
Contractor Name: Flatiron/Drill Tech, a Joint Venture
Contractor Address: 15335 Fairfield Ranch Rd, Chino Hills, CA 91709
Resident Engineer: Saeid Shakeri Structure Rep.: Azizollah Maghsoudloo
DIME Sample ID: 2022-10-27-47
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 10/27/2022
Date that the sample was received by the laboratory/organization performing the testing: 11/02/2022
The quantity of what the sample constitutes: 7
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Mfg. Lot Number(s): L031122
Material/Compound/Elastomer ID: NA
Samples Representing: 7
Description (size): 1X4X6
Comments:
Description (Number of Shims): 2
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA
DIME Test ID: 2022-10-27-47-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 11/15/2022
Date Tested: 11/08/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: Hardness
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
52
|
Reading #2
|
51
|
Reading #3
|
51
|
Reading #4
|
51
|
Reading #5
|
52
|
Mean
|
51.4
|
DIME Test ID: 2022-10-27-47-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 11/15/2022
Date Tested: 11/08/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.083
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2972.91 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.084
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2781.02 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.083
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2867.53 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2867.5 lbf/in^2
|
DIME Test ID: 2022-10-27-47-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 11/15/2022
Date Tested: 11/08/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.074
|
Sample 1 Tear Strength
|
262.3
|
Sample 2 Median Thickness
|
0.078
|
Sample 2 Tear Strength
|
266.3
|
Sample 3 Median Thickness
|
0.072
|
Sample 3 Tear Strength
|
261.5
|
Median of the Tear Strength Values
|
262.3 lb/in
|
DIME Test ID: 2022-10-27-47-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 11/08/2022
Date Tested: 11/08/2022
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: