STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 033H3304 Cty YOL Rte 50 PM 2.5/3.2,L0.0/18.3

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Jody Phillips

Date Reported:

11/29/2022

Address:

TL Number:

294801

City:

Project Name: INSTALL CMS, FIBER OPTIC CABLE SYSTEMS AND CAMERA SYSTEMS.

Prime Contractor: STUDEBAKER BROWN ELECTRIC, INC.

Sample Taken Date:

11/01/2022

Mix Design:

CT590

Contractor: Unknown

Location: YOLO COUNTY AND SACRAMENTO COUNTY ON ROUTE 50 FROM JEFFERSON BOULEVARD TO 1.3 MILES EAST OF FOLSOM BOULEVARD

Structure unique identifier:

Structure name:

Location of Pour:


The following testing has been tested in accordance with:

ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0212.69361002844.01
24.0212.69389343068.01
34.0112.633863830591

DIME Test ID: 2022-11-01-31-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 2990
Age of specimen: 7 days
Certified By: Spencer Adams


ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0112.63502503979.02
24.0112.63516014086.01
34.0112.635129140611

DIME Test ID: 2022-11-01-31-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4040
Age of specimen: 28 days
Certified By: Phillip Montes


ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0112.63544904315.01
24.0112.63575324555.01
34.0112.635920046871

DIME Test ID: 2022-11-01-31-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4520
Age of specimen: 28 days
Certified By: Spencer Adams



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing