Print Report | Back to Sample Detail

Sample Record for 2015-07-02-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 208862 DEA: 080K7104 EFIS: 0800000366 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15,215-14.0/R16.4,16.0/17.8
Work Description: I-15/I-215 Interchange Improvements (Devore)
Location Description: On I-15 from 0.8 mile south of Glen Helen Parkway UC to 1.4 mile north of Kenwood Ave UC And On I-215 from 1.2 mile south of Devore Road OC to the I-15 junction
Contractor Name: Atkinson Construction,, LLC
Contractor Address: 1672 Devore Road, San Bernardino, CA 92407
Resident Engineer: Owen Spencer Structure Rep.: Scott Gueltzow

Sample Information

DIME Sample ID: 2015-07-02-6
TL Number from the TL Form: 180602
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/02/2015
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2015
The quantity of what the sample constitutes: 2
A brief description of the sample: Concrete 6 x 12
From where was the sample collected: Job Site
Laboratory sample identification: 868-02
Structure unique identifier: Unknown
Structure name: Bridge 4 Devore OH
The fabricator/manufacturer/facility name: Holliday

Material Information

The concrete mix design number: CT1-C4400DI
The truck number from where the sample was collected: 620
The batch plant ticket number from where the sample was collected: 10303847
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Plant
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: CIP DECK
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2015-07-02-6-1
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/13/2015
Date Tested: 08/13/2015
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 4990 psi
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 42 days