Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04264724 Cty MRN Rte 101 PM R20.8/27.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Fabio La Serna |
Date Reported: |
11/15/2022 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
||||
Prime Contractor: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO) |
||||
Sample Taken Date: |
10/18/2022 |
Mix Design: |
3728LV |
|
Contractor: Unknown |
Location : MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
|||
Structure unique identifier: 27-0092L |
||||
Structure name: Olive Ave UC - Widen SB |
||||
Location of Pour: Olive Ave UC Abut 1 3 wall Soffit to TOP |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 12.63 | 4.01 | 5951.0 | 75159 | 1 |
2 | 12.69 | 4.02 | 6028.0 | 76506 | 2 |
3 | 12.57 | 4.00 | 6442 | 80951 | 1 |
DIME Test ID: 2022-10-18-49-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6140
Age of specimen: 28 days
Certified By: Phillip Montes
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing