Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 031H2704 Cty YUB Rte 70 PM R11.2/13.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Selvendran Manoharan |
Date Reported: |
11/16/2022 |
|
Address: |
TL Number: |
87460 |
||
City: |
||||
Project Name: UPGRADE BRIDGE RAILS & CONSTRUCT CONCRETE MEDIAN BARRIER. |
||||
Prime Contractor: BRIDGEWAY CIVIL CONSTRUCTORS, INC. |
||||
Sample Taken Date: |
10/19/2022 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location: YUBA COUNTY NEAR LINDA AND MARYSVILLE FROM 2.4 MILES SOUTH OF FEATHER RIVER BOULEVARD UNDERCROSSING TO THE YUBA RIVER BRIDGE AND OVERHEAD |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 50357 | 3967.0 | 1 |
2 | 4.02 | 12.69 | 52478 | 4135.0 | 1 |
3 | 4.02 | 12.69 | 56888 | 4482 | 1 |
DIME Test ID: 2022-10-19-15-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4190
Age of specimen: 7 days
Certified By: Ryan Crawford
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 66445 | 5288.0 | 1 |
2 | 4.01 | 12.63 | 71341 | 5649.0 | 1 |
3 | 4.01 | 12.63 | 74393 | 5891 | 1 |
DIME Test ID: 2022-10-19-15-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5610
Age of specimen: 28 days
Certified By: Ryan Crawford
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing