Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 034F0704 Cty SAC Rte 50 PM 17.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Joseph Estepa |
Date Reported: |
07/20/2015 |
|
Address: |
TL Number: |
Unknown |
||
City: |
||||
Project Name: WIDEN STRUCTURE, EXTEND WEAVE LANE, AND ADD RAMP METERING. |
||||
Prime Contractor: DE SILVA GATES CONSTRUCTION |
||||
Sample Taken Date: |
06/22/2015 |
Mix Design: |
F628AFST0 |
|
Contractor: Unknown |
Location: SACRAMENTO COUNTY AT NATOMA OVERHEAD |
|||
Structure unique identifier: 24 0120 |
||||
Structure name: Natoma OH |
||||
Location of Pour: Bent 4 Columns |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 27.99 | 5.97 | 4032.0 | 112855 | 1 |
2 | 27.9 | 5.96 | 4103.3 | 114482 | 1 |
DIME Test ID: 2015-06-22-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4070
Age of specimen: 28 days
Certified By: Mike Mullins
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 27.9 | 5.96 | 3828.7 | 106822 | 1 |
2 | 27.99 | 5.97 | 3811.1 | 106674 | 1 |
DIME Test ID: 2015-06-22-3-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3820
Age of specimen: 21 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing