Project Information

Project ID: 993802 DEA: 041W8804 EFIS: 0421000104 QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-101-R54.2/R56.2
Work Description: COLD PLANE AC PAVEMENT AND PLACE RHMA (TYPE G).
Location Description: SONOMA COUNTY NEAR CLOVERDALE FROM ROUTE 101/128 SEPARATION TO MENDOCINO COUNTY LINE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: LEONARD BRAJNIKOFF Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-09-07-94
TL Number from the TL Form: 670375
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/07/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/18/2022
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: rubber
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 1
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2022-09-07-94-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/27/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 26 0.1 mm

Test 2 of 4

DIME Test ID: 2022-09-07-94-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 11/07/2022. The corrected test ID is: 2022-09-07-94-4
Reason: retested

Test 3 of 4

DIME Test ID: 2022-09-07-94-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/27/2022
Date Tested: 10/25/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 56 mm
Ball Penetration (P1) 0 mm
Final Dial reading (F2) 60 mm
Ball Penetration (P2) 0 mm
Final Dial reading (F3) 58 mm
Ball Penetration (P3) 0 mm
Resilience 1 44 %
Resilience 2 40 %
Resilience 3 42 %
Average Resilience 42 %
Minutes Reaction no data

Test 4 of 4

DIME Test ID: 2022-09-07-94-4
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/07/2022
Date Tested: 11/03/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
The test was superseded from test ID: 2022-09-07-94-2
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 74 C
Softening Point Sample 2 74 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data