Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 100S1104 Cty SJ Rte 4 PM Var Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Harminder Deol |
Date Reported: |
08/19/2015 |
|
Address: |
TL Number: |
89937 |
||
City: |
||||
Project Name: SR-4 FREEWAY EXTENSION |
||||
Prime Contractor: BROSAMER & WALL, INC. |
||||
Sample Taken Date: |
06/24/2015 |
Mix Design: |
628452R7 |
|
Contractor: Unknown |
Location : IN SAN JOAQUIN COUNTY |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 27.9 | 5.96 | 3290.2 | 91797 | 1 |
2 | 28.37 | 6.01 | 3339.4 | 94739 | 1 |
DIME Test ID: 2015-06-24-8-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3310
Age of specimen: 7 days
Certified By: Bang Nguyen
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.37 | 6.01 | 3834.1 | 108772 | 1 |
2 | 27.99 | 5.97 | 3538.9 | 99054 | 1 |
DIME Test ID: 2015-06-24-8-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3690
Age of specimen: 14 days
Certified By: Bang Nguyen
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.09 | 5.98 | 4463.8 | 125389 | 1 |
2 | 27.99 | 5.97 | 4180.4 | 117008 | 1 |
DIME Test ID: 2015-06-24-8-3
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4320
Age of specimen: 28 days
Certified By: Bang Nguyen
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 27.99 | 5.97 | 4853.6 | 135853 | 1 |
2 | 27.99 | 5.97 | 5021.2 | 140544 | 1 |
DIME Test ID: 2015-06-24-8-4
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4940
Age of specimen: 42 days
Certified By: Bang Nguyen
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 27.99 | 5.97 | 5005.9 | 140116 | 1 |
2 | 27.99 | 5.97 | 4834.7 | 135322 | 1 |
DIME Test ID: 2015-06-24-8-5
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4920
Age of specimen: 56 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing