Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214336 DEA: 07302404 EFIS: 0713000488
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-101-37/40
Work Description: PADRE JUAN REHAB
Location Description: VEN 101
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4820 McGrath Street, Suite 101, Ventura, CA 93003
Resident Engineer: Alfred Ira Structure Rep.: Unknown
DIME Sample ID: 2022-10-01-5
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Soil
Sample Taken Date: 10/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2022
The quantity of what the sample constitutes: 595 sq. yd.
A brief description of the sample: Aggregate Base
From where was the sample collected: Job Site
Laboratory sample identification: 22-2588
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: From various locations at Aggregate Base
Where the material sample would have been placed if not sampled:
DIME Test ID: 2022-10-01-5-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 10/13/2022
Date Tested: 10/01/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sum of Count or Density
|
6.15 g/cc
|
Average of Count or Density
|
2.05 g/cc
|
Sum of Moisture Count
|
0.7 g/cc
|
Average of Moisture Count
|
0.23 g/cc
|
Calculated Percent Relative Compaction
|
95.3 %
|
Reported Percent Relative Compaction
|
95 %
|
DIME Test ID: 2022-10-01-5-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 10/13/2022
Date Tested: 10/01/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is oversize material
|
No
|
In-place wet density
|
2.05
|
Highest adjust wet density
|
2.15
|
Relative compaction
|
95
|
% Moisture
|
12.6 %
|
Optimum Moisture
|
14.1 %
|