Print Report | Back to Sample Detail

Sample Record for 2022-10-08-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993801 DEA: 032G3704 EFIS: 0321000118 QA Service Level: 1
DIST-CO-RTE-PM: 03-COL,YOL-16-0.1/7.3,0.0/0.7
Work Description: PARTIAL DEPTH RECYCLING, PLACE RHMA-G, & COLD PLANE AC PAVEMENT.
Location Description: COLUSA AND YOLO COUNTIES NEAR RUMSEY FROM 0.1 MILE SOUTH OF ROUTE 20 TO 1.3 MILES NORTH OF ROAD 40
Contractor Name: BALDWIN CONTRACTING CO. INC DBA KNIFE RIVER CONSTRUCTION
Contractor Address: 1764 SKYWAY ROAD, CHICO, CA 95928
Resident Engineer: Masoud Saed Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-10-08-2
TL Number from the TL Form: 875256
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Department Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 10/08/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/10/2022
The quantity of what the sample constitutes: 1 cans
A brief description of the sample: 64-16
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2022-10-08-2-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 10/14/2022
Date Tested: 10/13/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 29 0.1 mm

Test 2 of 2

DIME Test ID: 2022-10-08-2-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 10/14/2022
Date Tested: 10/13/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 66 mm
Ball Penetration (P1) 0 mm
Final Dial reading (F2) 61 mm
Ball Penetration (P2) 0 mm
Final Dial reading (F3) 64 mm
Ball Penetration (P3) 0 mm
Resilience 1 34 %
Resilience 2 39 %
Resilience 3 36 %
Average Resilience 36 %
Minutes Reaction no data