Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993505 DEA: 022J4404 EFIS: 0221000078
QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-139-38.0/43.0
Work Description: REPLACE AC SURFACING, ASPHALT RUBBER BINDER, SEAL COAT & HMA OVERLAY.
Location Description: LASSEN COUNTY ABOUT 37 MILES NORTH OF SUSANVILLE FROM 4.3 MILES NORTH OF SOUTH GRASSHOPPER ROAD TO 0. 2 MILE SOUTH OF TERMO GRASSHOPPER ROAD
Contractor Name: Hat Creek Construction
Contractor Address: 24339 Highway 89 N, Burney, CA 96013
Resident Engineer: Daniel Gibbs Structure Rep.: Unknown
DIME Sample ID: 2022-09-24-16
TL Number from the TL Form: 897871
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/24/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/05/2022
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1 pan of Lime Treated 1/2-inch Type A HMA (eq. PG 64-28 M) with 25.0% RAP and virgin PG 58-34 M from Albina (Klamath Falls, OR)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79175
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction and Materials – Shaw Pit Facility (Lookout, CA)
DIME Test ID: 2022-09-24-16-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/07/2022
Date Tested: 10/06/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
no data
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
5.95 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.32 %
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|