Print Report | Back to Sample Detail

Sample Record for 2022-09-29-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993495 DEA: 120S2104 EFIS: 1219000106 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-R24.0/37.7
Work Description: APPLY METHACRYLATE TREATMENT AND REPLACE JOINT SEALS AND BEARING PADS.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM S5-N133 CONNECTOR SEPARATION IN IRVINE TO BALL ROAD OVERCROSSING IN ANAHEIM
Contractor Name: J. FRANCIS COMPANY
Contractor Address: 766 Palmyrita Ave, Suite C, Riverside, CA 92507
Resident Engineer: Mike Ezzedine Structure Rep.: Noah Bruton

Sample Information

DIME Sample ID: 2022-09-29-26
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 09/29/2022
Date that the sample was received by the laboratory/organization performing the testing: 10/03/2022
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 21693-2
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 4.03x16x24
Comments:
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2022-09-29-26-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 10/12/2022
Date Tested: 10/05/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 55
Reading #2 52
Reading #3 52
Reading #4 52
Reading #5 52
Mean 52.6

Test 2 of 4

DIME Test ID: 2022-09-29-26-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 10/12/2022
Date Tested: 10/05/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 5
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.055
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2226.14 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.055
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2578.1 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.055
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 1993.45 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Sample 4 Median Thickness 0.055
Sample 4 Thickness all Within 0.003 inch? Yes
Sample 4 Ultimate Tensile 2513.54 lbf/in^2
Sample 4 Elongation (350% Min) Pass
Sample 5 Median Thickness 0.055
Sample 5 Thickness all Within 0.003 inch? Yes
Sample 5 Ultimate Tensile 2766.6 lbf/in^2
Sample 5 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2513.5 lbf/in^2

Test 3 of 4

DIME Test ID: 2022-09-29-26-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 10/12/2022
Date Tested: 10/05/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.055
Sample 1 Tear Strength 230.8
Sample 2 Median Thickness 0.055
Sample 2 Tear Strength 243.4
Sample 3 Median Thickness 0.055
Sample 3 Tear Strength 209
Median of the Tear Strength Values 230.8 lb/in

Test 4 of 4

DIME Test ID: 2022-09-29-26-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 10/06/2022
Date Tested: 10/06/2022
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass