Print Report | Back to Sample Detail

Sample Record for 2022-09-15-65

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215374 DEA: 060X2704 EFIS: 0618000048 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-37.2/48.8
Work Description: PAVEMENT REHABILITATION
Location Description: FROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-09-15-65
TL Number from the TL Form: C026834
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/15/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/26/2022
The quantity of what the sample constitutes: 3 Boxes
A brief description of the sample: 1/2 RHMA-G
From where was the sample collected: Source
Laboratory sample identification: 022-069
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Coalinga HMA Plant

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number: 8
Sublot number: 15
HMA Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2022-09-15-65-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/30/2022
Date Tested: 09/29/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Method Performed Mechanical Agitation - Method A
Mass of oven-dry sample in air for Sample 1 1570.7 grams
Mass of sample in water for Sample 1 907.3 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.368
Theoretical maximum density at 25°C (77°F) 147.4 lb/ft^3

Test 2 of 3

DIME Test ID: 2022-09-15-65-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/30/2022
Date Tested: 09/29/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.2 %
Percent Air Voids 2 3.3 %
Percent Air Voids 3 3.3 %
Percent Air Voids Average 3.3 %

Test 3 of 3

DIME Test ID: 2022-09-15-65-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/30/2022
Date Tested: 09/29/2022
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.293
Bulk Specific Gravity 2 2.291
Bulk Specific Gravity 3 2.290
Average Bulk Specific Gravity 2.291