Sample Record for 2022-07-05-47
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Coffman Specialties
Contractor Address: 9685 Via Excelencia, San Diego, CA 92126
Resident Engineer: Elvira Lenart Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2022-07-05-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Department Acceptance
Type of Material: Aggregate
Sample Taken Date: 07/05/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2022
The quantity of what the sample constitutes: 1 Bag Combined Aggregate
A brief description of the sample: 3/8" HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt-Corona
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-33-0005
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: 106926
A detailed description of where the material sample was collected: Belt Cut at All American Corona Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2022-07-05-47-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/26/2022
Date Tested: 07/06/2022
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 3/8 in. sieve
|
97 %
|
Cumulative percent passing the #4 sieve
|
60 %
|
Cumulative percent passing the #8 sieve
|
40 %
|
Cumulative percent passing the #16 sieve
|
27 %
|
Cumulative percent passing the #30 sieve
|
19 %
|
Cumulative percent passing the #50 sieve
|
12 %
|
Cumulative percent passing the #100 sieve
|
8 %
|
Cumulative percent passing the #200 sieve
|
5 %
|
Test 2 of 2
DIME Test ID: 2022-07-05-47-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 09/26/2022
Date Tested: 07/06/2022
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: