Print Report | Back to Sample Detail

Sample Record for 2022-09-14-71

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993555 DEA: 061C4304 EFIS: 0621000166 QA Service Level: 1
DIST-CO-RTE-PM: 06-MAD-41,99-9.2/11.7,0.0/1.5
Work Description: COLD PLANE AC, PLACE RHMA-G AND HMA (TYPE A).
Location Description: MADERA COUNTY NEAR MADERA ON ROUTE 41 FROM 0.7 MILE SOUTH OF ROAD 209 TO 0.3 MILE NORTH OF ROAD 208 AND ON ROUTE 99 FROM MADERA COUNTY LINE TO 0.7 MILE SOUTH OF AVENUE 8 OVERCROSSING
Contractor Name: CAL VALLEY CONSTRUCTION INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-09-14-71
TL Number from the TL Form: 027201
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 09/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/22/2022
The quantity of what the sample constitutes: 1 can
A brief description of the sample: PG64-16 Rubber Blend
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Madera Plant

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2022-09-14-71-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/30/2022
Date Tested: 09/29/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 49 0.1 mm

Test 2 of 3

DIME Test ID: 2022-09-14-71-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/30/2022
Date Tested: 09/29/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 62 C
Softening Point Sample 2 62 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2022-09-14-71-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/30/2022
Date Tested: 09/29/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 80 mm
Ball Penetration (P1) 3 mm
Final Dial reading (F2) 78 mm
Ball Penetration (P2) 1 mm
Final Dial reading (F3) 78 mm
Ball Penetration (P3) 1 mm
Resilience 1 23 %
Resilience 2 23 %
Resilience 3 23 %
Average Resilience 23 %
Minutes Reaction no data