Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215317 DEA: 101J0104 EFIS: 1018000079
QA Service Level: 1
DIST-CO-RTE-PM: 10-CAL,CAL-88,34-34.6/2.2
Work Description: Construct fuel island canopies.
Location Description: In Calaveras and Alpine counties on Route 26 at the West Point Maintenance Station and on Route 88 at the Caples Lake Maintenance Station.
Contractor Name: CAL ELECTRO, INC. - Valerie Jenkins
Contractor Address: 3710 Electro Way, Redding, CA 96002
Resident Engineer: Pawan Garg Structure Rep.: Brandon Thurber
DIME Sample ID: 2022-09-23-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Department Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 09/23/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/26/2022
The quantity of what the sample constitutes: 48
A brief description of the sample: 1.25" Anchor Bolt Gr 36
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Portland Bolt
Rocap Number(s):
Heat Number(s): 3116497
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: 1554 gr 36
Bolt Length(s): 32
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 1.25 x 32
Bolt Mfg. Lot Number: 3116497
Rocap Test Requirement(s): no
Lubricant Requirements(s): yes
DIME Test ID: 2022-09-23-5-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/04/2022
Date Tested: 10/03/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1A | 3116497 | 0.503 | 0.199 | 59530 | 77785 | 31.3 | spaine |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2022-09-23-5-2
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/04/2022
Date Tested: 10/03/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 3116497 | 0.504 | 0.2 | 59320 | 77753 | 33 | spaine |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2022-09-23-5-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/04/2022
Date Tested: 10/04/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3116497
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BLUE
|
Size
|
1.25 in
|
Bolt Length
|
32 in
|
Gage Type
|
Pass
|
DIME Test ID: 2022-09-23-5-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/04/2022
Date Tested: 10/04/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3116497
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BLUE
|
Size
|
1.25 in
|
Bolt Length
|
32 in
|
Measurement Average
|
5.61 mils
|