Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 032F5704 Cty PLA Rte 80 PM 46.3/63.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Tad Sampson |
Date Reported: |
10/20/2022 |
|
Address: |
TL Number: |
188837 |
||
City: |
||||
Project Name: Replace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay) |
||||
Prime Contractor: Walsh Construction Company II, LLC (Walsh) |
||||
Sample Taken Date: |
09/22/2022 |
Mix Design: |
7815-WSR6 |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.02 | 28.46 | 120036 | 4217.0 | 3 |
2 | 6.02 | 28.46 | 138449 | 4864.0 | 3 |
DIME Test ID: 2022-09-22-18-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4540
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 177021 | 6240.0 | 1 |
2 | 6.00 | 28.27 | 166075 | 5874.0 | 1 |
DIME Test ID: 2022-09-22-18-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6060
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing