Print Report | Back to Sample Detail

Sample Record for 2022-09-21-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213707 DEA: 081C38U4 EFIS: 0817000196 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Coffman Specialties
Contractor Address: 9685 Via Excelencia, San Diego, CA 92126
Resident Engineer: Elvira Lenart Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-09-21-26
TL Number from the TL Form: 62
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/23/2022
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 1012-62A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: coffman

Material Information

The concrete mix design number: np
The truck number from where the sample was collected: 72
The batch plant ticket number from where the sample was collected: 27
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: job
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-09-21-26-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/28/2022
Date Tested: 09/28/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.98 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 3 5.99 in
Average diameter of cylinder 4 5.99 in
Average diameter of cylinder 5 5.98 in
Average diameter of cylinder 6 5.99 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.09 in^2
Cross sectional area of cylinder 3 28.18 in^2
Cross sectional area of cylinder 4 28.18 in^2
Cross sectional area of cylinder 5 28.09 in^2
Cross sectional area of cylinder 6 28.18 in^2
Compressive strength (to nearest 10 psi) 550 psi
Maximum load on cylinder 1 15855 lb
Maximum load on cylinder 2 15155 lb
Maximum load on cylinder 3 15625 lb
Maximum load on cylinder 4 15420 lb
Maximum load on cylinder 5 15665 lb
Maximum load on cylinder 6 15790 lb
Compressive strength of cylinder 1 564.4 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 539.5 psi
Compressive strength of cylinder 3 554.5 psi
Compressive strength of cylinder 4 547.2 psi
Compressive strength of cylinder 5 557.7 psi
Compressive strength of cylinder 6 560.3 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Type of fracture pattern of cylinder 4 1
Type of fracture pattern of cylinder 5 3
Type of fracture pattern of cylinder 6 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Correction factor for cylinder 5 1
Correction factor for cylinder 6 1
Age of specimen 7 days
Age of specimen in hours 0 hours