Sample Record for 2015-06-05-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 5266 DEA: 08448404 EFIS: 0800000712 COOP: 081488A1 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91-15.6/21.6
Work Description: CONSTRUCT HOV LANES AND WIDEN BRIDGES.
Location Description: RIVERSIDE COUNTY IN RIVERSIDE FROM ADAMS STREET TO THE ROUTE 60/215 SEPARATION
Contractor Name: SEMA CONSTRUCTION INC
Contractor Address: 320 Goddard, Suite 150, , Irvine, CA 92618
Resident Engineer: Joseph Lopez Structure Rep.: Al-Hakem Alina

Sample Information

DIME Sample ID: 2015-06-05-1
TL Number from the TL Form: 01568
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/05/2015
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2015
The quantity of what the sample constitutes: 4
A brief description of the sample: Concrete cylinder
From where was the sample collected: Job Site
Laboratory sample identification: 825-68
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: Site

Material Information

The concrete mix design number: SC590B38
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: 1065171
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: DS 108e Manhole EZ at Vine st Form
Where the material sample would have been placed if not sampled: DS 108e Manhole EZ at Vine st
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2015-06-05-1-1
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/09/2015
Date Tested: 06/09/2015
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 2260 psi
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 4 days

Test 2 of 2

DIME Test ID: 2015-06-05-1-2
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/03/2015
Date Tested: 07/03/2015
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Compressive strength (to nearest 10 psi) 4140 psi
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 28 days