Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042J5304 Cty MRN Rte 1 PM 42.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Hal Streater |
Date Reported: |
05/27/2015 |
|
Address: |
TL Number: |
021725 |
||
City: |
||||
Project Name: Construct Solider Pile Wall |
||||
Prime Contractor: Valentine Corp. |
||||
Sample Taken Date: |
04/29/2015 |
Mix Design: |
4700 |
|
Contractor: Unknown |
Location: Near Tomales , at 2.8 miles south of Tomales-Petaluma Toad |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.18 | 5.99 | 7001.2 | 197294 | 1 |
2 | 28.27 | 6.00 | 7007.7 | 198109 | 1 |
DIME Test ID: 2015-04-29-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 7000
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing