Print Report | Back to Sample Detail

Sample Record for 2022-08-23-87

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993297 DEA: 010F8204 EFIS: 0116000067 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-R90.1/109.6
Work Description: PLACE RHMA-G AND HMA (TYPE A).
Location Description: IN HUMBOLDT COUNTY IN AND NEAR TRINIDAD FROM 1.3 MILES SOUTH OF SCHOOL ROAD OVERCROSSING TO 0.4 MILE NORTH OF BIG LAGOON BRIDGE
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: 77 West Second Street, Eureka, CA 95501
Resident Engineer: Ryan Dunne Structure Rep.: Michele Stover

Sample Information

DIME Sample ID: 2022-08-23-87
TL Number from the TL Form: 032403
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/23/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/25/2022
The quantity of what the sample constitutes: 1 Can
A brief description of the sample: Asphalt Rubber Binder PG 64-16
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Fortuna Plant B

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 4
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2022-08-23-87-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/22/2022
Date Tested: 09/21/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 31 0.1 mm

Test 2 of 2

DIME Test ID: 2022-08-23-87-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/22/2022
Date Tested: 09/21/2022
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 59 mm
Ball Penetration (P1) 2 mm
Final Dial reading (F2) 59 mm
Ball Penetration (P2) 3 mm
Final Dial reading (F3) 59 mm
Ball Penetration (P3) 2 mm
Resilience 1 43 %
Resilience 2 44 %
Resilience 3 43 %
Average Resilience 43 %
Minutes Reaction no data