Print Report | Back to Sample Detail

Sample Record for 2022-08-20-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993302 DEA: 081J2104 EFIS: 0817000240 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-60-R1.4
Work Description: PLACE LCB RAPID SETTING AND JOINTED PLAIN CONCRETE PAVEMENT.
Location Description: SAN BERNARDINO COUNTY IN CHINO AT RAMONA AVENUE OVERCROSSING
Contractor Name: RV CONCRETE INC
Contractor Address: 605 E. COMMERCIAL ST., ANAHEIM CA 92801
Resident Engineer: Xavier Avila Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-20-5
TL Number from the TL Form: 1043-2
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/20/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2022
The quantity of what the sample constitutes: 4
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1043-2
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RVC

Material Information

The concrete mix design number: Not Provided
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample: NA
A detailed description of where the material sample was collected: EB60 Ramona STA 6900
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-08-20-5-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Cured in accordance with ASTM C511
Verified Date: 08/29/2022
Date Tested: 08/27/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.37 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Compressive strength (to nearest 10 psi) 1590 psi
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.01 in
Compressive strength of cylinder 1 1555.9 psi
Compressive strength of cylinder 2 1632.2 psi
Maximum load on cylinder 1 44280 lb
Maximum load on cylinder 2 46305 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days