Print Report | Back to Sample Detail

Sample Record for 2022-08-11-54

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993439 DEA: 022J4204 EFIS: 0221000076 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-R26.3/29.8
Work Description: HMA OVERLAY AND REPLACE AC SURFACING.
Location Description: TRINITY COUNTY NEAR DOUGLAS CITY FROM BROWNS CREEK BRIDGE TO READING CREEK BRIDGE
Contractor Name: TULLIS INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-11-54
TL Number from the TL Form: 858101
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/11/2022
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 12 boxes of Lime Treated 3/8-inch Type A HMA with 25% RAP and virgin PG 58-34 M from Valero – Benicia
From where was the sample collected: Manufacturer
Laboratory sample identification: D79124
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis – Northstate Asphalt (Redding, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/8 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2022-08-11-54-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/26/2022
Date Tested: 08/15/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7335.8 grams
Mass of oven-dry sample in air for Sample 1 1573.8 grams
Mass of container filled with the sample and water for Sample 1 8273.4 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.474
Theoretical maximum density at 25°C (77°F) 154.0 lb/ft^3

Test 2 of 5

DIME Test ID: 2022-08-11-54-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/26/2022
Date Tested: 08/12/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.96 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.67 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 3 of 5

DIME Test ID: 2022-08-11-54-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/26/2022
Date Tested: 08/15/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.369
Bulk Specific Gravity 2 2.368
Bulk Specific Gravity 3 2.371
Average Bulk Specific Gravity 2.369

Test 4 of 5

DIME Test ID: 2022-08-11-54-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/26/2022
Date Tested: 08/15/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: VMA = 16.2%, VFA = 73.9%, DP = 1.3
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.2 %
Percent Air Voids 2 4.3 %
Percent Air Voids 3 4.2 %
Percent Air Voids Average 4.2 %

Test 5 of 5

DIME Test ID: 2022-08-11-54-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/26/2022
Date Tested: 08/23/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 132 psi
Average Wet Tensile Strength 122 psi
Tensile Strength Ratio 0.92