Sample Record for 2022-08-20-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993626 DEA: 070W0804 EFIS: 0721000034 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-28.0/31.6
Work Description: INDIVIDUAL SLAB REPLACEMENTS.
Location Description: LOS ANGELES COUNTY IN CULVER CITY AND LOS ANGELES FROM VENICE BOULEVARD SEPARATION TO WILSHIRE BOULEVARD UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd,, Westlake Village, CA 91361
Resident Engineer: Frank Shin Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-20-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 08/20/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/20/2022
The quantity of what the sample constitutes: 140 CY
A brief description of the sample: ISR-RSC Beams
From where was the sample collected: Job Site
Laboratory sample identification: 22-2141
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Security Paving - Florence

Material Information

The concrete mix design number: G3-220
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-08-20-2-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 08/23/2022
Date Tested: 08/23/2022
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test: SB Rte. 405 @ Santa Monica Blvd. Off-Ramp
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 3
Does the testing machine measure load or stress on the beam specimen? Load
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Is a beam dimensional correction factor used? No
Age of specimen 3 days
Modulus of rupture 520 psi
Modulus of rupture 2 500 psi
Modulus of rupture average 490 psi
Modulus of rupture 3 460 psi