Print Report | Back to Sample Detail

Sample Record for 2022-08-13-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993535 DEA: 081M1104 EFIS: 0821000078 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-215-10.0/17.2
Work Description: HMA, COLD PLANE AC PAVEMENT, AND TRAFFIC STRIPE TAPE.
Location Description: SAN BERNARDINO COUNTY?FROM 0.1 MILE NORTH OF 27TH STREET TO 0.1 MILE SOUTH OF DEVORE ROAD
Contractor Name: CALMEX ENGINEERING INC.
Contractor Address: 2764 S VISTA AVE, BLOOMINGTON, CA 92316
Resident Engineer: VuThanh Nguyen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-13-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/13/2022
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2022
The quantity of what the sample constitutes: 2 Boxes HMA 756.65 tons out
A brief description of the sample: 3/4" HMA-A-SP R23 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0556A-22
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan San Bernardino Portable

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2022-08-13-8-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/18/2022
Date Tested: 08/17/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.49 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data