Print Report | Back to Sample Detail

Sample Record for 2022-08-11-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-08-11-2
TL Number from the TL Form: na
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/11/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/29/2022
The quantity of what the sample constitutes: 7000
A brief description of the sample: 1" F959 DTI MG
From where was the sample collected: Fabricator
Laboratory sample identification: na
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): na
Heat Number(s): 115134
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): E5A-A
Bolt Specification: na
Bolt Length(s): na
Nut Specification: na
Washer Specification: F 959
Finish: MG
Diameter/Size: 1"
Bolt Mfg. Lot Number: na
Rocap Test Requirement(s): na
Lubricant Requirements(s): na

Test Results

Test 1 of 7

DIME Test ID: 2022-08-11-2-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.05 mils

Test 2 of 7

DIME Test ID: 2022-08-11-2-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.22 mils

Test 3 of 7

DIME Test ID: 2022-08-11-2-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.83 mils

Test 4 of 7

DIME Test ID: 2022-08-11-2-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.7 mils

Test 5 of 7

DIME Test ID: 2022-08-11-2-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.49 mils

Test 6 of 7

DIME Test ID: 2022-08-11-2-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1F
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.14 mils

Test 7 of 7

DIME Test ID: 2022-08-11-2-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/29/2022
Date Tested: 09/07/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1G
Rocap Number no data
Heat Number(s) 115134
Mfg. Lot Number E5A-A
Finish Coating ASTM B695 - Mech Galv
Product Markings E5A 325 120
Size 1 in
Bolt Length no data in
Measurement Average 4.52 mils