Sample Record for 2022-08-05-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993318 DEA: 11423704 EFIS: 1116000059 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R31.8/R41.7
Work Description: PLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location Description: SAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real, Ste 200, Carlsbad, CA 92008
Resident Engineer: Art Pannu Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2022-08-05-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 08/05/2022
Date that the sample was received by the laboratory/organization performing the testing: 09/09/2022
The quantity of what the sample constitutes: 404
A brief description of the sample: 1.5 inch dowels purple
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Highway Products

Material Information

Dowel Metal Heat Number: 4400012225
Dowel Epoxy Batch Number: 1G90B
Dowel Coating Specification: ASTM A934
Dowel Size: 1.5 in
Dowel Coating Color: Purple
Dowel Manufacturer: Pacific Highway Products
Dowel Coater: Simcoat Inc
Release Number:
Quality Assurance Code:
Rebar Size (#):

Test Results

Test 1 of 2

DIME Test ID: 2022-08-05-2-1
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 09/13/2022
Date Tested: 09/09/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 7.69 mils
Second Bar Mean 20.75 mils
Lower spec. limit LSL 7 mils
Upper spec. limit USL 12 mils
Total mean value 14.22 mils
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2022-08-05-2-2
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 09/13/2022
Date Tested: 09/09/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 3
Holidays Per Linear Foot of Bar 0
Holiday Test Pass/Fail Pass