Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214671 DEA: 07303904 EFIS: 0714000044
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-31.2/37.2
Work Description: LANE REPLACEMENT
Location Description: LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE EAST OF THE 10/605 SEPARATION TO 0.3 MILE WEST OF CITRUS STREET OVERCROSSING
Contractor Name: Sierra Landscape Development Inc.
Contractor Address: 2209 1/2 Chico Ave., South El Monte CA, 91733
Resident Engineer: Hai Hong Structure Rep.: Unknown
DIME Sample ID: 2022-07-30-12
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Sample Organization Contact: (909) 833-5780
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/30/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2022
The quantity of what the sample constitutes: 525 CY
A brief description of the sample: A set of 3 JPCP RSC beams
From where was the sample collected: Job Site
Laboratory sample identification: 22-1967
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Security Paving Plant - Baldwin Park
The concrete mix design number: G3-21-PRS-237
The truck number from where the sample was collected: Not Provided
The batch plant ticket number from where the sample was collected: Not Provided
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-07-30-12-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 08/11/2022
Date Tested: 08/10/2022
Submitted By Organization: Kleinfelder, Incorporated - Los Angeles
Organization Address: 620 South Magnolia Avenue, Building G,
Organization City: Ontario
Organization State: CA
Organization Zipcode: 91762
Organization Email: mdorsch@kleinfelder.com
Organization Phone: (909) 833-5780
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
3
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Fracture occurred at a capped section
|
No
|
Is a beam dimensional correction factor used?
|
No
|
Age of specimen
|
10 days
|
Modulus of rupture
|
655 psi
|
Modulus of rupture 2
|
600 psi
|
Modulus of rupture average
|
630 psi
|
Modulus of rupture 3
|
625 psi
|