Print Report | Back to Sample Detail

Sample Record for 2022-07-16-23

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Lane-Security Paving Joint Venture
Contractor Address: 3450 Centre Lake Drive, 1st Floor, Ontario, CA 91761
Resident Engineer: Jose Corona Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2022-07-16-23
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Sample Organization Contact: (760) 252-9216
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 07/16/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2022
The quantity of what the sample constitutes: 4 Bags Coldfeed Agg., 1 Bag Rap
A brief description of the sample: 1 x 4 PCC Aggregate and Sand
From where was the sample collected: Manufacturer
Laboratory sample identification: TEST 1 AT 2229 OF 10CY OUT
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LANEsecurity paving

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-36-0040
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: 220831 CORD SJR
A detailed description of where the material sample was collected: Belt Cut at Vulcan-Corona Drum
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 1-1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2022-07-16-23-11
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/29/2022
Date Tested: 07/18/2022
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 0 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 98 %
Cumulative percent passing the 3/4 in. sieve 67 %
Cumulative percent passing the 1/2 in. sieve 0 %
Cumulative percent passing the 3/8 in. sieve 20 %
Cumulative percent passing the #4 sieve 4 %
Cumulative percent passing the #8 sieve 1 %
Cumulative percent passing the #16 sieve 62 %
Cumulative percent passing the #30 sieve 40 %
Cumulative percent passing the #50 sieve 17 %
Cumulative percent passing the #100 sieve 5 %
Cumulative percent passing the #200 sieve 2 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2022-07-16-23-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory
2022-07-16-23-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates07/29/2022Not scheduledMinh PhamCT D08 - Fontana Southern Regional Laboratory