Print Report | Back to Sample Detail

Sample Record for 2022-07-26-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993493 DEA: 100Q1224 EFIS: 1014000168 QA Service Level: 1
DIST-CO-RTE-PM: 10-MER-99-28.2/R37.3
Work Description: WIDEN CONCRETE PAVEMENT LANES AND BRIDGES.
Location Description: MERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE
Contractor Name: SECURITY PAVING COMPANY, INC. - Bassel Jamaleddine
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Tofael Anwar Structure Rep.: Karen Sampson

Sample Information

DIME Sample ID: 2022-07-26-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 07/26/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/29/2022
The quantity of what the sample constitutes: 2
A brief description of the sample: Coupon Castings
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: dsi

Material Information

Heat Number (s): 1992 2002
Part Number (s): 68 27 246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): Dotson
Prestressing Manufacturer: DSI

Test Results

Test 1 of 1

DIME Test ID: 2022-07-26-27-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 08/04/2022
Date Tested: 08/01/2022
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
19920.5020.19792475757614320.4spaine
20020.5020.19792440946815720.5spaine
UTM 67kip
Temperature 72 F