Print Report | Back to Sample Detail

Sample Record for 2022-07-14-74

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993112 DEA: 021H4704 EFIS: 0216000044 QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-5-36.3/41.6
Work Description: ROADWAY EXCAVATION, HMA (TYPE A), CULVERT WORK AND RSP.
Location Description: TEHAMA COUNTY NEAR RED BLUFF FROM NINE MILE HILL OVERCROSSING TO 0.1 MILE NORTH OF BOWMAN ROAD OVERCROSSING
Contractor Name: BALDWIN CONTRACTING COMPANY INC. DBA. KNIFE RIVER CONSTRUC TION
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2022-07-14-74
TL Number from the TL Form: 859000
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2022
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 25.0% RAP and Virgin PG 58-34 M from Valero – Benicia
From where was the sample collected: Manufacturer
Laboratory sample identification: D79094
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis – Northstate Asphalt (Redding, CA)

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 6

DIME Test ID: 2022-07-14-74-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/29/2022
Date Tested: 07/18/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7335.7 grams
Mass of oven-dry sample in air for Sample 1 2522.5 grams
Mass of container filled with the sample and water for Sample 1 8854.2 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.512
Theoretical maximum density at 25°C (77°F) 156.4 lb/ft^3

Test 2 of 6

DIME Test ID: 2022-07-14-74-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/29/2022
Date Tested: 07/21/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.90 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.50 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 3 of 6

DIME Test ID: 2022-07-14-74-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/29/2022
Date Tested: 07/18/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.391
Bulk Specific Gravity 2 2.397
Bulk Specific Gravity 3 2.406
Average Bulk Specific Gravity 2.398

Test 4 of 6

DIME Test ID: 2022-07-14-74-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/29/2022
Date Tested: 07/18/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: VMA = 13.7%, VFA = 66.8%, DP = 1.3
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.8 %
Percent Air Voids 2 4.6 %
Percent Air Voids 3 4.2 %
Percent Air Voids Average 4.5 %

Test 5 of 6

DIME Test ID: 2022-07-14-74-5
Test Method: AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
Data has not been verified.

Test 6 of 6

DIME Test ID: 2022-07-14-74-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 07/29/2022
Date Tested: 07/27/2022
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 122 psi
Average Wet Tensile Strength 116 psi
Tensile Strength Ratio 0.95