Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040A0204 Cty SON Rte 1 PM 15-15.7 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Fabio La Serna |
Date Reported: |
08/30/2022 |
|
Address: |
TL Number: |
018253 |
||
City: |
||||
Project Name: Construct roadway and bridge with structural concrete and CIDH piling |
||||
Prime Contractor: BRIDGEWAY CIVIL CONSTRUCTORS, INC. |
||||
Sample Taken Date: |
07/19/2022 |
Mix Design: |
72105003R |
|
Contractor: Unknown |
Location : District-County-Route-Post Mile: 04-Son-1-R15.0/R15.7 |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 51867 | 4107.0 | 4 |
2 | 4.01 | 12.63 | 51690 | 4093.0 | 4 |
3 | 4.01 | 12.63 | 50069 | 3965 | 4 |
DIME Test ID: 2022-07-19-41-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4060
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 68368 | 5387.0 | 4 |
2 | 4.03 | 12.76 | 64606 | 5065.0 | 4 |
3 | 4.03 | 12.76 | 64258 | 5038 | 4 |
DIME Test ID: 2022-07-19-41-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5160
Age of specimen: 14 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.03 | 12.76 | 72010 | 5645.0 | 4 |
2 | 4.02 | 12.69 | 66202 | 5216.0 | 4 |
3 | 4.02 | 12.69 | 70269 | 5536 | 4 |
DIME Test ID: 2022-07-19-41-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5470
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.03 | 12.76 | 82341 | 6455.0 | 2 |
2 | 4.03 | 12.76 | 78453 | 6150.0 | 2 |
3 | 4.05 | 12.88 | 79328 | 6158 | 4 |
DIME Test ID: 2022-07-19-41-4
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6250
Age of specimen: 42 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
![]() |
TL- Report of Laboratory Testing